Diese Seite ist nur auf Englisch verfügbar.

Equipment

Microscope systems and current configurations (updated 04/2021)

  • Confocal microscopes (1-4)

  • TIRF/ScannerFRAP microscope (5)

  • Widefield screening microscope (6)

  • Widefield microscopes (7-11)

  • Micromanipulation/-injection system (12)

  • Stereomicroscopes & macroscopes (13-14)

Current Equipment

1. Zeiss LSM 780 confocal microscope

  • Microscope stand: Zeiss Axio Observer, inverted microscope
  • Laser: 405 nm pulsed diode laser, 30 mW / 458 nm, 488 nm, 514 nm Argon laser, 25 mW / 561 nm DPSS laser, 20 mW / 633 nm HeNe laser, 5 mW
  • (pulsed) in Tune laser 490-640 nm, 1.5 mW per wavelength
  • Objectives: Plan-APOCHROMAT 20x/0,80 Air / C-APOCHROMAT 40x/1.2 W Korr-UV-VIS-IR / Plan-APOCHROMAT 40x/1.3 Oil / Plan-APOCHROMAT 63x/1.4 Oil / Plan-APOCHROMAT 100x/1.4 Oil
  • Software: Zeiss ZEN 2010
  • Room -132

2. Leica TCS SP5 confocal microscope

  • Microscope stand: Leica DMI 6000 CS Trino, inverted microscope
  • Laser: 405 nm diode laser, 50 mW / 458 nm, 5 mW, 76 nm, 5mW, 488 nm, 20 mW, 514 nm, 20 mW Argon laser / 561 nm DPSS laser, 20 mW / 633 nm HeNe laser, 10 mW
  • Objectives: HC PL APO 10x/0.40 CS Air / HCX PL APO 20x/0.70 IMM CORR Lbd BL / HCX Plan APO 40x/1.30 Oil CS / HCX PL APO 63x/1.20 W CORR CS / HCX PL APO 63x/1.30 GLYC CORR CS / HCX PL APO 63x/1.40-0.60 Oil Lbd BL
  • 2 Hybrid GaAsp detectors (HyD) and 3 PMTs
  • Tandem scanning system
  • Incubation chamber w/ Temp & CO2 control (LIS)
  • Software: Leica Application Suite (LAS)
  • AFC (hardware autofocus)
  • Room -132

3. Leica DMi8 Spinning Disk microscope

  • Microscope stand: Leica DMi8, inverted microscope
  • Confocal Scanner Unit: Yokogawa CSU-X1
  • Laser: 405 nm, diode laser / 488 nm, 50 mW diode laser / 561 nm, 50 mW diode laser / 640 nm, diode laser
  • Objectives: HC PL FLUOTAR 25x/0.8 IMM CORR / HC PL APO 40x/1.3 Oil / HC PL APO 63x/1.40-0.60 Oil / HC PL APO 100x/1.4 Oil CS2
  • Cameras: Hamamatsu EMCCD ImagEM Enhanced (C9100-13) / Hamamatsu Orca Flash 4.0 LT (C11440-42U)
  • Adaptive Focus Control (AFC)
  • Software: MetaMorph Advanced Acquisition
  • Incubation chamber XL & Pecon temperature control unit
  • Room -132

4. Leica TCS SP8 STED 3X microscope with FALCON FLIM

  • Microscope stand: Leica DMi8, inverted microscope
  • Laser: White light laser (WLL), 470-670 nm, pulsed
  • STED lasers for superresolution: 592 nm, 1.5 W / 660 nm, 1.5 W / 775 nm, >1.5 W
  • Objectives: HC PL FLUOTAR 10x/0.30 Air / HC PL APO 20x/0.75 IMM CORR Lbd BL / HCX PL APO 63x/1.40 Oil CS2 / HC PL APO 93x/1.30 GLYC motC STED W / HC PL APO 100x/1.40 STED White Oil
  • 2 Hybrod GaAsp detectors (HyD) and 2 PMTs
  • gated STED
  • 3D STED 3X
  • Software: Leica Application Suite X (LASX)
  • FALCON for FLIM, FLIM-FRET, TauSTED and Phasor
  • Room -132

TIRF/ScannerFRAP widefield microscope:

5. Olympus xcellence TIRF/ScannerFRAP

  • Microscope stand: Olympus IX81, inverted microscope
  • Olympus cellTIRF 4-Line Motorized TIRF Combiner
  • TIRF Lasers: 405 nm, 100 mW / 488 nm, 100 mW / 561 nm, 100 mW / 640 nm, 140 mW
  • Olympus cellFRAP module
  • ScannerFRAP Laser: 514 nm, 100 mW
  • Objectives: UPLSAPO 60x/1.35 Oil DIC / PLAPO 100x/1.45 Oil DIC
  • MT 20 illumination system: 150 W Xe or 150 W Hg/Xe arc burner / Fast filter wheel
  • Filters: Dualband CFP/YFP sbx HC filter set / Dualband GFP/mCherry sbx ET filter set / Quad DAPI/FITC/Cy3(Texas Red)/Cy5 sbx HC filter set / TIRF Quad
  • Cameras: Olympus XM10 / Hamamatsu ImagEM Enhanced (C9100-13)
  • Software: Olympus xcellence
  • ZDC (hardware autofocus)
  • Incubation chamber w/ Temp and CO2 control units
  • TMC Linos optical table 63-550
  • Room -132

Widefield screening microscope:

6. Olympus ScanR screening/CellSens system

  • Microscope stand: Olympus IX81, inverted microscope
  • Objectives: UPLSAPO 20x/0.75 Air / UPLSAPO 40x/0.95 Air / UPLFL N 60x/0.90 Air / PLAPO 100x/1.45 Oil
  • Lumencor Spectra X illumination system
  • Filters for: DAPI / CFP / GFP / YFP / RFP/mCherry / Cy5
  • Camera: Hamamatsu Orca Flash 4.0
  • Software: Olympus ScanR_2.5.0 & CellSens
  • ZDC (hardware autofocus)
  • Incubation chamber w/ Pecon temp control
  • Room -144

Widefield microscopes:

7. Olympus CellSens microscope

  • Microscope stand: Olympus IX81, inverted microscope
  • Objectives: UPLSAPO 10x/0.4 Air / UPLSAPO 20x/0.75 Air / UPLSAPO 40x/0.95 Air DIC / UPLSAPO 60x/1.35 Oil / PLAPO 100x/1.45 Oil DIC
  • Lumencor Spectra X illumination system
  • Filters: Dualband CFP/YFP sbx HC filter set / Dualband GFP/mCherry sbx ET filter set / Quad DAPI/FITC/Cy3(Texas Red)/Cy5 sbx HC filter set / Single band GFP / Single band mCherry
  • Camera: Hamamatsu ORCA-R2
  • Software: Olympus CellSens
  • ZDC (hardware autofocus)
  • Room -144

8. Nikon BioStation IM-Q Time Lapse Imaging System

  • For glass bottom dishes
  • Objectives: 40x (20x, 40x, 80x by switching tube lens), NA 0.8,
  • Filters: Ex 438/24, Em 483/32 CFP/Cerulean / Ex 472/30, Em 520/35 GFP / Ex 500/24, Em 542/27 YFP / Ex 562/40, Em 624/40 Alexa568/mCherry/TxRed
  • Camera: 1.3-megapixel cooled monochrome camera
  • Software: Nikon
  • Room -144

9. Applied Precision (GE) PersonalDV

  • Objectives: UPlanSApo 10x/0.40 Air / UPlanSApo 20x/0.75 Air / UPlanSApo 40x/0.95 Air / UPlanSApo 20x/0.85 Oil / UApo/340 40x/1.35 Iris Oil / PlanApo N 60x/1.42 Oil
  • Filters: Dichroic 1: GFP & RFP / Ex 490/20, Em 528/38 / Ex 555/28, Em 617/73 / Dichroid 2: CFP & YFP & mCherry / Triple „Sedat“ sbxm ET Filterset 
  • Camera: Photometrics CoolSNAP HQ2
  • Software: Resolve3D/softWoRx
  • UltimateFocus (hardware autofocus)
  • Environmental Chamber
  • TMC optical table 63-534
  • Room -144

10. Leica DMRXA, upright microscope

  • Objectives: N Plan 5x/0.12 PH0 Air / HC PL Fluotar 10x/0.30 PH1 Air / HC PL Fluotar 20x/0.50 PH2 Air / PL Fluotar 40x/0.70 PH2 Air / PL APO 40x/1.25-0.75 Oil / PL APO 63x/1.0 W CORR / PL APO 100x/1.40-0.7 Oil
  • Filters: Ex 340-380, Em LP 425 (DAPI) / Ex BP 450-490, Em LP 515 (FITC) / Ex 470/40, Em BP 525/50 (GFP) / Ex 470/40, Em LP 500 (EGFP) / Ex BP 620/60, Em LP 700/75 (Cy5) / Ex 531-560, Em BP 574-648 (TexasRed) / Ex BP 436/20, Em BP 480/40 (CFP) / Ex BP 560/40, Em BP 645/75 (Cy3)
  • Camera: Hamamatsu ORCA-ER (C4742-95-12ER)
  • Software: Micro-Manager
  • Room -144

11. Zeiss AxioObserver

  • Microscope stand: Zeiss Axio Observer Z1
  • Objectives: LD-Plan-NEOFLUAR 20x/0.4 Air Ph2 / LD-Plan-NEOFLUAR 40x/0.6 Air Ph2 / LD-Plan-NEOFLUAR 40x/1.3 Oil DIC / Plan-APOCHROMAT 63x/1.4 Oil DIC / Plan-NEOFLUAR 100x/1.3 Ph3
  • Filters: Ex BP 340-380, Em LP 425 / Ex BP 450-490, Em BP 515-560 / Ex 530-595, Em LP 615 / Ex 570/50, Em 640/40
  • Camera: AxioCam MRm
  • Software: AxioVision
  • Colibri LED light source
  • Definite Focus (hardware autofocus)
  • Incubation chamber w/ CO2 ModuleS and TempModuleS
  • Room -144

Micromanipulation/-injection system:

12. AIS 2 micromanipulation system

  • Microscope stand: Zeiss Axiovert 10, inverted microscope
  • Injection system: Luigs & Neumann, Germany
  • Injection pressure system: Eppendorf FemtoJet
  • Objectives: ACHROSTIGMAT 5x/0.12 Air / ACHROSTIGMAT 10x/0.25 Air / ACHROSTIGMAT 20x/0.30 Air Ph1 / ACHROSTIGMAT 32x/0.40 Air Ph1 / Plan NEOFLUAR 40x/0.75 Air
  • Filters: F41-017 HQ-Set EGFP / F41-021 HQ-Set Cy 3,5
  • Camera: ImagingSource DMK2002
  • Software: AIS 2 control program
  • Room -144

Stereomicroscopes & macroscopes:

13. Leica MZ FLIII fluorescence stereomicroscope

  • Filters: GFP2, CFP, UV, G(reen) ex.
  • Cold light source: Leica KL 1500 LCD
  • Fluorescence light source: Leica HXP 120W
  • Camera: ProgRes C10plus (optional)
  • Software: Micro-Manager
  • Room -144

14. Leica M420 macroscope

  • Cold light sources: Leica KL 1500 LCD & Zeiss KL 2500 LCD
  • Camera: ProgRes C10plus (optional)
  • Software: Micro-Manager
  • Room -144